Sevcon gen4 fault codes pdf 2. Fault Codes: BT-280, RE-380 […] Nov 14, 2022 · Hello A year ago I bought an electric scooter for around $60 with dead batteries. After some digging, I thought it could be a CAN termination issue and I cut the P1 pad connection on the CANBus shield. Jan 25, 2012 · Getting the program into the sevcon is 0. In some cases, there are multiple possible causes for a fault in that category. With over 50 years of experience and development centre’s in Gateshead UK, Oxford UK, Kitchener Canada and Lugo Italy, Sevcon offers unsurpassed experience and maturity in a rapidly growing and evolving electrification market. If you have a 4 flash check the following. The handset features password protected access levels and a Jan 25, 2012 · Hi everyone, thanks for the responses! 1. I have put 4. Check encoder wiring. So far so good, but than i set to operation mode and recycle key, i get a HeartBeat fault from the canBus, LED flashes 12 times and you are again not able to run the motor. Sevcon Gen4 ; Sevcon MillipaK 4QPM ; Sevcon Categories Page 68: Fault Clearance Drive 1 On checks (failsafe circuit disabled). 32 sales. To make changes to the Gen4 parameters you need to enable the Personalities and Configuration screens. If this part seems difficult to you, you're in for a long trip down frustration lane, and it's no fault of the controller or whoever sold it to you, it's just the nature of setting up an ultra tuneable controller like a Sevcon Gen4. It's a port of my SEVCON core functionality from the OVMS project, with a simple command interface on the Arduino serial port. Sevcon Gen4 Fault Identification (short version) You can identify a fault as follows: Check the number of LED flashes and use below to determine what action to take. The controller when powered on emits three green blinks, and the Sevcon datasheet tells me that either a software fault or bad MOSFETs. The first thing to do is connect the PcPak to the controller. pdf","path":"documents sales. Check PST condition. Page 26 Gen4, Nano, Evo5, GpAC and espAC Fault Codes Level LED Flashes Type Display Message Description Recommended Action EMCY message received from non-Sevcon node and anonymous 0x5381 Very Severe F44101 CANopen anon EMCY level 4 Check status of non-Sevcon nodes on CANbus EMCY level (0x2830,0) is set to 4. txt) or view presentation slides online. 1979 Honda CB750K + Sevcon Gen4 Size4 + Brushless Etek + 2 * A123 12S8P pack = EtekChopper! Sevcon_Master_Object_Dictionary_Database - Object Dictionary. I’m scratching my head. 202 MillipaK controller pdf manual download. Mar 10, 2015 · This Is How I Programmed A Sevcon Gen 4!!! (Link) [youtube]yMH7Z1aJeSs[/youtube] I am pretty new to the forums, so let me first introduce myself. Sevcon Gen4 ; Sevcon Categories. This caused the internal fault. 12001 (no other device will work) Jan 21, 2021 · I bought DLC28 me1302 motor , sevcon gen4 size6 550A set about 2years ago. Sevcon PowerpaK SEM & MicropaK Manual w/ Calibrator Section. Sevcon SC2000 Manual w/ Calibrator Section . I tested the 3 Hall sensors and 2 were bad. 10200 (w/galvanic isolation) USB to CAN adapter, Sevcon part # 661/30132. Starting DVT: Click and Start DVT. May 25, 2016 · Sevcon Gen 4 Fault Question: Changing CAN Node. sales. The motor came to me with a bad Encoder. I've built short press on the enter button will cause the fault history help screen to be shown. I am able to switch on successfully and I can enable drive (forward direction). 202 Dong-Ah Heights Bldg 449-1 Sang-Dong Wonmi-Gu Bucheon City Gyeounggi-Do 420-816 Korea T +82 32 215 5070 sales. Sevcon DVT Customer Manual . 0281. Controller Apr 19, 2019 · 4 Flash. Gen4 to ME0907 - 4-11-12. Currently I am communicating with the ClearView through a Sevcon (on the same CAN bus). • This code will disable all functions Thermal cutback. Dec 4, 2015 · Sevcon Gen 4 Controller Manual this is a link to a pdf that covers the controller fault blink list. Most faults are a result of a fault in the control system that will require service by a qualified Taylor-Dunn Dealer. This is almost always caused by a loose connection. Check line contactor, shorted motor cables to B+ 3 days ago · Emergency (EMCY) codes from the Sevcon Gen4 drives Can messages looks like this: ID b0 b1 b2 b3 b4 b5 b6 b7 "81";"00 31 04 C3 4D 00 00 00" "81";"00 31 14 C3 4D 00 00 00" Sevcon Controller Diagnostic Chart The Sevcon controller is identified by its blue case 5 Diagnostic Codes 1) A Light Emitting Diode (LED) is used to indicate controller status. Subsequently I had a diver cleaning the anti-foul and he found masses of fishing line wrapped around the propellor. It outlines the installation procedure which includes physical installation of the controller, initial wiring, and self-characterization. 32 73266 Bissingen an der Teck Germany T: +49 (0)170 9980294 E: de. After this i have no fault in pre-operation mode. All testing, fault-finding and adjustment should be carried out by competent personnel. or wait to hear back from Sevcon. So the question is how exactly did you manage to get the communication back up and manage to flash a new May 19, 2023 · It seems there are a few people around here who know a thing or two about the Sevcon Gen 4 Size 8. Apr 21, 2010 · sevcon/Sevcon Gen4 Motor Controller Firmware/Sevcon Gen4 Motor Controller Firmware/Firmware UK319_38B: 2014-03-17 23:13: sevcon/Sevcon Gen4 Motor Controller Firmware/Sevcon Gen4 Motor Controller Firmware/Firmware UK319_38B/G4827: 2014-03-16 15:46 Apr 5, 2020 · Its got a size 6 Gen4 Sevcon controller in it, and I'm pretty sure that's the broken part. 17 System State This document defines fault codes and messages for a SEVCON controller. com Sevcon, Inc. . 9. xx00 19. com Sevcon USA, Inc. I also found the fault codes from the sevcon gen 4 PDF and will look into getting a CAN Bus IXXAT so I can link to a PC running the drive wizard software. Electric Drive Engineering are the official distributors of Sevcon products in Australia and New Zealand Read the SEVCON Gen4 manual for some basic description. They seem pretty pricey at 900 euros!!! hopefully, i can find a cheaper one. Mechanic's Assistant: What's the approximate mileage on your '11 Ranger? From the factory it comes with a Sevcon Gen4 Size 2 with a PMAC (I think) motor. The vehicle will possibly give you a cut back Jan 25, 2012 · I discovered that For the Zero sevcon opertation No matter the baud rate you set in the main screen (not the DVT Helper) the sevcon remain programmed at the baud rate set in the DCF Next task: isolate all related motor parameters from the 2013 zero S dcf file and put them to my 2012 zero S dcf to have my 2013 motor to operate! sales. It lists 27 different fault codes including descriptions such as "Fan Fault" for no speed feedback from external fans, "BDI Warning" for low battery charge level, and "Device too hot" which reduces power to the motor due to high heat-sink temperature. com Sevcon SA 12 Rue Jean Poulmarch 95100 Argenteuil France Tel +33 (0)1 34 10 95 45 Fax +33 (0)1 34 10 61 38 sales. (PDT SPRINT 5000W) from 2011. 155 Northboro Road Southborough MA 01772 T: 508 281 5510 F: 508 281 5520 us. Page 73 OVMS: Renault Twizy User Guide 2019/05/02 RT3. Jan 25, 2012 · And I will soon have a post up on how to program the Sevcon Gen 4 using the IXXAT converter and the DVT software. pages 7-5 thru 7-9 how to i chech for all those fault codes . Once I got time to check over the vehicle, I found some pretty bad corrosion on the battery terminals inhibiting current. Recently I had a fail with my electric motor installation on my yacht which I couldn't immediately diagnose. This document covers some DVT basics. View online or download Sevcon Gen4 Applications Reference Manual. 202 Dong-Ah Heights Bldg 449-1 Sang-Dong Wonmi-Gu Bucheon City Gyeounggi-Do 420-816 Korea Tel +82 32 215 5070 sales. Note that fault codes vary by product line. pdf), Text File (. sevcon. • Extensible SEVCON OBJECT and SEVCON SECTION compatibility, ensuring the future compatibility of all new Sevcon EDS and XML files. 3) If the controller is faulty, the LED will be OFF. Sevcon PowerpaK Codes . com Sevcon Japan 4-12-1 Shinbashi Minato-Ku, Tokyo 105-0004 Japan LED Diagnostic Guide for Sevcon PRO-99050 Controller The Sevcon Controller Flash Code Diagnostic Guide can be used to get an initial indication of a problem. xls" there are hints in there that may be helpful. kr@sevcon. com Sevcon SAS Parc d’Activité du Vert Galant Rue Saint Simon St Ouen l’Aumône 95041 Cergy Pontoise Cedex France T +33 (0)1 34 30 35 00 sales. 95041 Cergy Pontoise Cedex France Tel +33 (0)1 34 30 35 00 Fax +33 (0)1 34 21 77 02 sales. From the manual the six flashes seem to indicate over or under voltage on input or output or throttle greater than 20% at start up. Have fun! Jan 25, 2012 · hello, kiwi, thanks for the answer, I will tell you the background, this motorcycle zero 2014 is out of order bms because in our country it is impossible to find any components or a dealer, I assembled a new battery and put ant-bms, the throttle stick consists of 2 electronic potentiometers, I removed the mbb from the motorcycle and connected all the wires to the controller but got stuck with jp. Controller Sevcon Gen4 Applications Reference Manual Write the fault ID to sub-index 1 and read back the fault description from sub-index 2. fr@sevcon. button Any fault after that might be relevant. adjustments and allows them to monitor status of a Sevcon Gen4 motor controllers. Some Taylor-Dunn vehicles show fault codes when a component of the vehicle is malfunctioning. I am not able to get the SEVCON talk with the CAN and the helper says no nodes on the BUS. The causes and verification steps for some fault codes related to system input sales. Lately I've got a lot of Lithium-ion battery packs from old kick scooters, so I decided to give it a try and see if I can make it running again. Please contact Sevcon for assistance with this process. A range of models is available to suit a wide number of applications and cooling regimes. Requirements: - IXXAT Model - 1. 32 73266 Jul 2, 2024 · 2011 Bad Boy Classic Sevcon 4 Flash Fault Electric golf carts Sevcon fault code 6??? Electric EZGO: All times are GMT -5. This chapter provides a detailed catalog of commonly used Sevcon controllers, such as the GEN4 and GEN3 series. A; Page 2 Sevcon Limited (Head Office) Kingsway South Gateshead NE11 0QA England T: +44 (0)191 497 9000 F: +44 (0)191 482 4223 uk. I know for a fact that the company used to modify the Sevcon configuration using the Sevcon's Calibration programming tool (as opposed to the DVT software). The drive wheels should be off the floor and free to rotate during the following procedures. This will give you a better explanation of the fault code. pdf. com Sevcon Japan 4-12-1 Shinbashi Minato-Ku, Tokyo 105-0004 Japan Jun 29, 2014 · I seem to have the same problem. Upgrading the controller software It is possible to field update the firmware of the Dragon8 controller, typically using Sevcon’s DVT configuration tool. 32 Curtis F Series Troubleshooting and Fault Codes; Sevcon PowerpaK SEM & MicropaK SEM ; Sevcon MillipaK 4Q Manual; Sevcon Millipak 4Q Wiring (old) Sevcon Millipak 4Q Wiring Sevcon MillipaK SBPM Manual; Sevcon Gen4 G4827/G4845/G4865 Data Sheets; Sevcon Gen4 G4827/G4845/G4865 Product Manual; Gen4 fault codes (short version) Gen4 Simplified Wiring LED Diagnostic Guide for Sevcon PRO-99050 Controller The Sevcon Controller Flash Code Diagnostic Guide can be used to get an initial indication of a problem. A diagram of the unit is shown in Figure 1. Attempting to set too many faults. Analogue input voltage is outside allowable range. The picture is referring to the DC SEVCON controller. Check motor condition/wiring. It describes: - The diagnostic LED flashes 1-10 times to indicate different faults, such as a personality out of range, illegal start condition, MOSFET short circuit, contactor fault, accelerator/speed sensor wire fault, low/high battery voltage, over temperature, and encoder or CAN bus ing and logging, fault code detection, ANOpen iA402 controller, J1939 controller, PI loop tuning tools, encoder alignment tools Programming Dongle IXXAT US to AN Interface V2 1. THE VEHICLE MANUFACTURER'S MANUAL SHOULD BE CONSULTED BEFORE ANY OPERATION IS ATTEMPTED. The Screen will appear as shown Mar 5, 2013 · I eliminated the source of the encoder fault and found that the node-id was 0, range is 1-127. Aug 24, 2020 · At this point the sevcon resorted to a fault with the LED flash in six times. Page 9 Note: You will see a sequence fault if not started in neutral this code will clear as soon as you put the car in neutral. com Sevcon Japan 4-12-1 Shinbashi Minato-Ku, Tokyo 105-0004 Japan Sep 5, 2016 · ANyone know about sevcon millipak codes for Bad boy buggy I have a Bad Boy Buggy 2007 CLassic I think, The 4 wheel drive isnt working and someone told us that the rear controller needed replacing. MillipaK 4QPM Controller Manual Page 68 13/08/03 Page 69: Fault Reporting Form Free essays, homework help, flashcards, research papers, book reports, term papers, history, science, politics Dec 1, 2023 · You will be disappointed take a look Sevcon Gen4 IXXAT Interface and DVT Software Though I also found this place which sells the software alone for much cheaper : Sevcon DVT Configuration Software + 3 year license - Electric Drive Engineering but I don't know how legit is that. 67. I have tested the input into the Sevcon and it is normal. You had to send a reset command via ODBD-2. com Sevcon Japan KK sales. Fault Codes. com Sevcon Inc 155 Northboro Road Southborough MA01772 USA T +1 (508) 281 5500 sales. but I did programming by DVTC but there was something wrong in process so the controller doesn’t work now first the controller flash long green light and blinking twice I tried several things from enless sphere forum to unbrick my gen4 size6 but everything wasn't work Sevcon MillipaK Pdf User Manuals. Sevcon Gen4 controllers are designed to control 3-phase AC induction motors and Permanent Magnet AC ( PMAC) motors in battery powered traction and pump applications. Sevcon PowerpaK Series Manual w/ Calibrator Section. I wonder if anyone has seen this issue. Software. com Sevcon SAS Parc d’Activité du Vert Galant Rue Saint Simon St Ouen l’Aumône 95041 Cergy Pontoise Cedex France Tel +33 (0)1 34 30 35 00 Fax +33 (0)1 34 21 77 02 sales. Thread starter methods; Start date May 25, 2016; methods 1 GW. Fault identification You can identify a fault as follows: Check the number of LED flashes and use below to determine what action can be taken. Pick up the EMCY on the CANbus and read the fault condition using configuration software Fault detected on PST power steer module. fr Sevcon Controller Diagnostic Chart The Sevcon controller is identified by its blue case 5 Diagnostic Codes 1) A Light Emitting Diode (LED) is used to indicate controller status. com Sevcon Japan 4-12-1 Shinbashi Minato-Ku, Tokyo 105-0004 Japan Internal controller fault Fxxyyy Led on 7F 8F 10F 6F 2F 2F 2F 2F 2F 7F 7F 7F 1F 1F 9F 3F 4F 4F off A / F1 F2 / B- power wiring, MOSFETs s/c. I found the controller - Its a Sevcon Millipak Part #633T45312 and S/N 2007070268 Aug 23, 2021 · Does one expect the sevcon gen 4 to clear fault codes without intervention if the fault condition is ameliorated, or is intervention required? With my old Toyota Highlander hybrid it always required intervention if a fault code was triggered. In the top left-hand corner is a LED indicator. 16 Pers Checksum 19. Click Here For DC Flash Codes Gen4, Nano, Evo5, GpAC and espAC Fault Codes Level LED Flashes UID FID Type Display Message Description Recommended Action 1 2 1 0x4481 Warning F12001 Handbrake Fault Handbrake is active when direction selected. uk@sevcon. These fault codes will apply to the older 4 post, 5 post (633C43104) and the current 6 post (633T45316) models. Sevcon offers a range of configuratio tools for the Gen4, ranging from PC based software with CAN connection dongle to our Calibrator handset unit. com Aug 23, 2020 · At this point the sevcon resorted to a fault with the LED flash in six times. {"payload":{"allShortcutsEnabled":false,"fileTree":{"documents/Manuals":{"items":[{"name":"2019-06-25-Rapport-de-configuration-ME0913-96V. The causes and verification steps for some fault codes related to system input This document provides diagnostic information for an SEVCON PowerpaK controller, including: 1. Sevcon Micropak - PowerpaK Codes. Before installing DW, first ensure that the IXXAT driver is installed correctly by following Section 3. We have 1 Sevcon Gen4 manual available for free PDF download: Applications Reference Manual. Release handbrake 1 5 1 0x4541 Warning F15001 Fan Fault No speed feedback from external heatsink fans Check operation of heatsink fans 11 Encoder fault, Check encoder wiring and encoder, repair as needed 12 Communication error, Check CANbus wiring, repair as needed 13 Internal software fault, cycle key 14 3rd Party Anonymous Node EMCY received, cycle key 15 Vehicle service required, severe fault sales. There four mounting holes, one in each corner of the metal heatsink. 5 %âãÏÓ 10 0 obj > endobj 27 0 obj >/Filter/FlateDecode/ID[]/Index[10 28]/Info 9 0 R/Length 84/Prev 25056/Root 11 0 R/Size 38/Type/XRef/W[1 2 1]>>stream These are not returned by the PWR-BattCell command call but must be retrieved separately using command code 32. The company I purchased the motor kit from says to just replace the encoder. This document provides information about the object dictionary for a CANopen master device. A complete fault code chart can be found in manual. Jun 2, 2017 · I need to put in some hours to figure out how to do this. This is a minimalistic SEVCON Gen4 configuration shell for Arduino. These tools provide a convenient and powerful means of accessing the Gen4 for diagnostic information or parameter adjustment. Python library to interact with Sevcon Gen4 inverter via CANOpen - brtiberio/Sevcon_gen4 MOS 90 controller pdf manual download. Sevcon MOS90 Codes. com Sevcon Japan 4-12-1 Shinbashi Minato-Ku, Tokyo 105-0004 Japan This document provides guidance on setting up and configuring a Gen4 vehicle controller. 3. Kansai Office 51-26 Ohyabu Hikone Shiga Japan 522-0053 Tel: +81 (0) 7 49465766 jp. Manuals and User Guides for Sevcon Gen4. The time now is 08:08 PM. It then discusses installing application software, verifying motor control and encoder functionality, setting up PDO maps, basic driver controls, tuning speed control Gen4 Sevcon Ltd Kingsway South Gateshead NE11 0QA England T +44 (0191) 497 9000 sales. • Sevcon internal temperatures above 176 degrees F • Will limit motor speed in comparison with over temperature • Resets when cooled Battery voltage at or below 18 volts • As measured on pin #1 • This code will interrupt or prevent lift function but will allow drive and steer Sevcon Gen4 Size 6 The SEVCON Gen4 Size 6 motor controller is designed to control 3-phase Permanent Magnet Alternating Current (PMAC) motors for traction and pump applications. Sevcon Gen4 Pdf User Manuals. Sevcon Gen4 controllers are designed to control 3-phase AC induction motors and Permanent Magnet AC (PMAC) motors in battery powered traction and pump applications. info@sevcon. com Sevcon Asia Ltd Code Interpretation Notes 0x2401 : Login 0x3441 : Host SW Upgrade 0x3442 : DSP SW Upgrade 0x34C1 : Watchdog Reset 0x45C1 : BDI Warning Battery Discharge Indicator's remaining charge is less than warning or cutout levels. I am assuming the sevcon is similar. Each pack is 10s4p = 36v so I have communication with Gen4 (contained within DVT software) • Application Notes: o CANopen Multi Node Setup o Gen4 Controlling Contactors via CANopen o Gen4 Controlling Motors via CANopen o Gen4 size8/10 J1939 H-Protocol using CANalyzer o J1939 H-protocol o Gen4 Encoder Configuration o Gen4 Thermistor configuration Jan 25, 2012 · I get no fault codes but, motor does not spin. 4) If there is a vehicle fault the LED will flash. 155 Northboro Road Southborough, MA 01772 USA Tel (508) 281 5500 Fax (508) 281 5341 sales. 5 IXXAT compatible with the Sevcon Gen4 controller? This document provides information about diagnostic LED faults on a SEVCON MicropaK - PowerpaK controller. we are using a hand drill to spin the motor, so I think out rotation is good. 3; Page 2 St Ouen l’Aumône 95041 Cergy Pontoise Cedex France Tel +33 (0)1 34 30 35 00 Fax +33 (0)1 34 21 77 02 sales. 43. 3 phase 48v 275a, which comes out to about 13kw. Controlling the Gen 4 as a Master via CAN It is possible to configure multiple Sevcon Master Controllers on one CANbus and utilise the higher level traction control to provide speed\torque ramping, controller\motor fault detection and the additional features associated with a Sevcon master within the object ranges 0x2000-0x2FFF. Fault messages are displayed on calibration tools and the LED, following a Fxxyyy format to indicate fault sales. Page 1 Gen4 Applications Reference Manual Document no: 177/52701 Rev. com follow @Sevcon www. com Sevcon Japan 4-12-1 Shinbashi Minato-Ku, Tokyo 105-0004 Japan Gen4, Nano, Evo5, GpAC and espAC Fault Codes Level LED Flashes Type Display Message 1 2 Warning F12001 Handbrake Fault 1 5 Warning F15006 No Motor Speed Signal Jul 26, 2021 · No matter what commands I send, I always get the SEVCON OFFLINE response. Sevcon MOS90 Manual w/ Calibrator Section. Sevcon Controller Models and Specifications: Choosing the Right Controller Sevcon offers a diverse range of controller models, each designed for specific applications and power requirements. 15 SN ID 2 xx00 19. Table 11: Fault Numbers and Descriptions Fault Clearance Any fault indication will be cleared by re-initiating the start sequence after the cause of the fault has been removed. V1 supported only reading & writing SDO registers and entering/leaving pre-operational mode. Jun 23, 2021 · I Have a Sevcon Gen 4 controller and a motenergy ME1115 PMAC motor that is constantly giving me DSP encoder faults. 1 Function Code Parameters Results & Remarks which: 1 = Alerts (not resettable, do power cycle) 2 = Fault events 3 = System events 4 = Counters 5 = Min/max log 99 = all Aug 24, 2020 · At this point the sevcon resorted to a fault with the LED flash in six times. when I take the trace I have the forward switch (we are using a three position switch to switch between forward, reverse, and The first 8 of the faults on the screen are fault checks which are created at the time the vehicle is the first programmed. Joined Aug 8, 2008 Messages 5,620 Location Santa Cruz Page 1 Clearview Display Reference Manual Document no: 177/5250x Rev. I am a senior in Mechanical Engineering at MIT, and a member of the MIT Electronics Research Society, which is a makerspace for MIT students to work on their own personal projects for fun. Take a look at the data @ the [100A] entry in the dcf and see if it compatible with the firmware version you loaded. Most registers of interest for normal tuning have been documented in the OVMS Twizy SDO list. com Sevcon SAS Parc d'Activité 4. Open circuit fault. The faults shown in this article are for reference only. • Improved Sevcon Display and Nano controller compatibility. 202 Dong-Ah Heights Bldg 449-1 Sang-Dong Wonmi-Gu Bucheon City Gyeounggi-Do 420-816, Korea Tel: +82 32 215 5070 sales. A complete and comprehensive fault identification table will be available from Sevcon in due course. View online or download Sevcon MillipaK Manual Fault Clearance. The fault history help screen is not accessible if the fault history is empty. 14 SN ID 1 xx00 19. 2) When operating normally, the LED will be ON continuously. com Sevcon Japan 4-12-1 Shinbashi Minato-Ku, Tokyo 105-0004 Japan 2. It provides detailed information on the meaning and implications of each SEVCON Fault Code Meanings Message Description Fan Fault No speed feedback from external heat-sink fans BDI Warning BDI remaining charge (0x2790,1) The controller is located near the axle or motor. us@sevcon. 1 Electric vehicles can be dangerous. A 4 flash is almost always caused by a loose connection. It's contained in the SEVCON DVT package. This screen will show the detailed fault help text for each fault in the log. com Sevcon SAS Parc d’Activité du Vert Galant Rue Saint Simon St Ouen l’Aumône . A diagnostic LED on the front of the controller indicates fault codes through a number of flashes. 0087. Is the v1. K. This is now %PDF-1. Fault code: 0X52c1 Encoder input wire-off is detected. Throttle demand is greater than 20% at power up. Both forward and reverse selected. 01. - CD with DVT software, provided by Sevcon. Unable to establish current in motor. 13 SN Date Code 0100 1299 0000 19. pdf - Free download as PDF File (. Sevcon DVT Customer: The Sevcon Gen4 controller is throwing a “11” code, which is defined as a voltage input problem. Ranging from no fault to issues like over temperature, low/high battery voltage, and more. For each model, we'll specify its key Jun 4, 2017 · Take a look at the "sevcon controller fault codes. 3 %âãÏÓ 6 0 obj /Linearized 1 /O 8 /H [ 753 181 ] /L 23986 /E 22074 /N 1 /T 23749 >> endobj xref 6 16 0000000016 00000 n 0000000664 00000 n 0000000934 00000 n 0000001085 00000 n 0000001231 00000 n 0000001468 00000 n 0000002021 00000 n 0000002226 00000 n 0000002265 00000 n 0000002445 00000 n 0000004257 00000 n 0000012367 00000 n 0000019289 00000 n 0000021966 00000 n 0000000753 00000 Sevcon MillipaK 4QPM Pdf User Manuals. 001% of the difficulty in programming a sevcon to work WELL with a motor. I may need to remove the Gen 4 from the buss and have DVT target only the ClearView either way I was warned that they can be bricked so I am moving slowly. View online or download Sevcon MillipaK 4QPM Manual Fault Finding. Support Jan 10, 2020 · Thanks, guys, all very helpful. CAN bus fault condition detected on multinode system. Replaced all 3 anyway and resoldered the wires going into the encoder board (all inside the motor). Number of LED flashes 0 (off), no light at all Internal hardware failure or no power to pin1. The full register set is documented in the SEVCON master dictionary, which is ©SEVCON. Although unlike your case, I just one GEN4 and I am facing the exact same problem after uploading a new DCF file. The DC/DC converter is normal as well. In DVT, I can go operational, and use the CANopen 402 demand generator to enable drive. com Sevcon Asia Ltd Room No. Kansai Office 51-26 Ohyabu Hikone Shiga Japan 522-0053 Tel +81 (0) 7 49465766 jp. com Sevcon Germany Hintere Str. com Sevcon Japan K. Incorrect start procedure fault. %PDF-1. jbsl glln hcbh pnveyj bpeqw xupcips ydkrxh uueek snfkt hvatj